Revision as of 21:39, 14 November 2013
This filter is a new development. There are three major changes in comparison to the filter described in External Filters
- The filter's passband is smaller than the previous 3 pole filter
- It has a massive DC short on both, the input and the output for static electricity and lightening protection
- The size is about half of the 3 pole filter of the first generation
The 3 pole filter type 2 (both ports SMA female) | Passband measured on a R&S FSEA with tracking generator |
- Technical data:
- passband attenuation: 0.5 dB
- -3 dB bandwidth: better than 9 MHz
- Options
- Standard connectors are two SMA female connectors
- The filter can made with N-female, N-male or BNC-female connectors each separately for both ends.
- Both connectors can be placed on the same side
- We can attach a massive M6 or M8 bolt on the side wall for a grounding strip
- Dimensions
- Length approximately 112 mm
- Width approximately 30 mm
- Height approximately 70 mm plus length of connectors
- Weight approximately 0,275 kg (SMA female connectors)
Note that due to the connector options there are small predrills visible on the optional connector locations.