Accessories:1090MHz 3 Pole Filter (Type 2): Difference between revisions
Jump to navigation
Jump to search
imported>Dl4mea mNo edit summary |
imported>Dl4mea No edit summary |
||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
[[File:Filter1.jpg|500px|thumb|1090MHz 3 Pole Filter Type 2<br \>(both ports SMA female)]] | |||
[[File:3poleType2 narrow.jpg|500px|thumb|Passband measured on a R&S FSEA with tracking generator<br \>Upper: wideband showing 10dB bandwidth/div<br \>Lower: narrow band, high resolution, showing 3dB bandwidth}]] | |||
This filter is a new development. There are three major changes in comparison to the filter described in [[Accessories:External Filters|External Filters]] | This filter is a new development. There are three major changes in comparison to the filter described in [[Accessories:External Filters|External Filters]] | ||
* The filter's passband is smaller than the previous 3 pole filter | * The filter's passband is smaller than the previous 3 pole filter | ||
* It has a massive DC short on | * It has a massive DC short on the input and the output protecting the connected devices from static electricity and lightening (*1) | ||
* The size is about half of the 3 pole filter of the first generation | * The size is about half of the 3 pole filter of the first generation | ||
* Technical data: | * Technical data: | ||
Line 30: | Line 28: | ||
Note that due to the connector options there are small predrills visible on the optional connector locations. | Note that due to the connector options there are small predrills visible on the optional connector locations. | ||
(*1) Not guaranteed a 100% protection, as there are other destructive ways. |
Latest revision as of 06:25, 22 November 2013
This filter is a new development. There are three major changes in comparison to the filter described in External Filters
- The filter's passband is smaller than the previous 3 pole filter
- It has a massive DC short on the input and the output protecting the connected devices from static electricity and lightening (*1)
- The size is about half of the 3 pole filter of the first generation
- Technical data:
- passband attenuation: 0.5 dB
- -3 dB bandwidth: better than 9 MHz
- Options
- Standard connectors are two SMA female connectors
- The filter can made with N-female, N-male or BNC-female connectors each separately for both ends.
- Both connectors can be placed on the same side
- We can attach a massive M6 or M8 bolt on the side wall for a grounding strip
- Dimensions
- Length approximately 112 mm
- Width approximately 30 mm
- Height approximately 70 mm plus length of connectors
- Weight approximately 0,275 kg (SMA female connectors)
Note that due to the connector options there are small predrills visible on the optional connector locations.
(*1) Not guaranteed a 100% protection, as there are other destructive ways.